7N Hydrogen Purification System
The 7N Hydrogen Purification System consists of two main parts: the gas circuit and the electronic control.
The gas circuit includes multiple parallel catalyst purification units, a series of pneumatic valves, gas pipelines, and heat
exchangers. This system uses a combination of chemical reactions and physical adsorption at room temperature to remove impurities such as H2O, O2, CO2, CO, and NMHC from the process gas, reducing them to less than 5 parts per billion (ppb). It can be equipped with particle filters with a filtration precision of 0.003 microns.
The electronic control part includes a PLC (Programmable Logic Controller), temperature controllers, and a touch screen. This part manages the purification, regeneration, and safety alarm processes, ensuring the purification system operates continuously, safely, and stably.
The gas circuit includes multiple parallel catalyst purification units, a series of pneumatic valves, gas pipelines, and heat
exchangers. This system uses a combination of chemical reactions and physical adsorption at room temperature to remove impurities such as H2O, O2, CO2, CO, and NMHC from the process gas, reducing them to less than 5 parts per billion (ppb). It can be equipped with particle filters with a filtration precision of 0.003 microns.
The electronic control part includes a PLC (Programmable Logic Controller), temperature controllers, and a touch screen. This part manages the purification, regeneration, and safety alarm processes, ensuring the purification system operates continuously, safely, and stably.

Flow Range: 10-20,000 Nm³/h
Impurity Content in Outlet Gas: Less than 5 ppb for each impurity
Particle Filter: 0.003 μm
Purification Tank: 316L Stainless Steel
Design: Multiple purification units designed for in-situ regeneration after saturation
Operation: Fully automatic operation for continuous gas supply
Impurity Content in Outlet Gas: Less than 5 ppb for each impurity
Particle Filter: 0.003 μm
Purification Tank: 316L Stainless Steel
Design: Multiple purification units designed for in-situ regeneration after saturation
Operation: Fully automatic operation for continuous gas supply