LPCB Photoelectric Smoke Detector LZ-1905
Description
1) Monthly Testing: Press the test button on the cover of the unit and hold it until the alarm sounds. If the alarm does not go off, check if the unit is receiving power and test it again. If it still doesn't alarm, check the battery and replace it immediately if needed.
2) Visual Indicators: The signal light on the unit flashes once every 30 seconds to indicate that it is functioning properly. When the alarm goes off, the signal light will flash once every 0.5 seconds.
3) Low Battery Warning: If the alarm emits a low "chirp" sound every 30 seconds, it means the battery needs to be replaced.
4) False Alarms: Normal smoke from cooking or small amounts of smoke will not trigger the alarm. False alarms occur only if you blow smoke directly into the alarm or if you forget to turn on ventilation while cooking.
5) Smoke Activation: Sometimes, smoking near the unit may trigger the alarm. In such cases, simply ventilate the area to stop the alarm from sounding.
Product Description
•1 year battery life time
•DC 9V battery operated
•Photoelectric chamber of early detection from all directions.
•Loud>85db(A)alarm signal(3M)
•Flash alarm indicator(red LED)
•Test/Hush associative button
•Low Battery signal
•Replaceable battery 1Y/3Y/5Y
• N.W.: ≈ 136g(include battery)
• Dimensions: Ф100*36.5mm
Product Parameter
Model No.
LZ-1905
Standard
EN14604:2005/AC:2008
Voltage
DC 9V
Standby current
≤10uA
Alarm current
≤30mA
Sensor type
Photoelectric
Temperature
0°C~+40°C
Ambient Humidity
≤95%R.H
Hush time
8~9min
Alarm indication
Red LED & Buzzer
Sound pressure
≥85dB(around 3m)
Weight
≈136g(incl.battery)
Product size
Φ100*36.5mm
Installation way
Ceiling mounting
Applicable place of smoke detector
${currentPro.title}