Portable LCD CO Detector with Import Sensor
Description
The LZ-2902 pairs a sealed decade-long lithium cell with a live LCD readout, so it tells you the carbon monoxide level in the room in ppm — not just that something is wrong.
10-year sealed battery 85 dB at 10 ft 101 x 101 x 32 mm EN50291-1:2018What's built in
Sealed-in lithium battery
The lithium cell is sealed in at the factory and sized for the alarm's full 10-year service life — nothing to swap, and nothing that can be pulled out or left uninstalled.
Digital LCD display
The screen reports the current CO concentration in ppm and refreshes every 15 seconds, so the reading reflects what's in the room right now.
Peak level memory
The display can call up the highest concentration recorded since the last reset — useful for understanding what happened while no one was watching.
Auto-activation
Mount it on the bracket and it starts monitoring on its own, with no separate power-on step.
Test/Menu button
The same button verifies the alarm is working correctly and mutes it when needed.
How an electrochemical sensor reads CO
The Figaro electrochemical sensor lets carbon monoxide react at an internal electrode. That reaction produces a small electrical current proportional to the CO concentration in the air, which the alarm converts directly into the ppm figure on the display.
Faster response, higher concentration
The alarm's response time is graded to the concentration it detects — low readings are logged without an immediate alarm, while dangerous levels trigger a response within minutes.

Three lights, three states
A glance at the LED tells you the status without reading the screen.

Sized for a wall or ceiling mount
Two views, to scale, for anyone specifying the install.
Technical specification
|
Model no. |
LZ-2902 |
|
Sensor type |
Figaro electrochemical sensor |
|
Sensor lifespan |
Max. 10 years |
|
Executive standard |
EN 50291-1:2018 |
|
Operating voltage |
DC3V (built-in CR17450 lithium) |
|
Battery life |
Max. 10 years |
|
Alarm output |
LCD, visual + audible |
|
Audio alarm |
85 dB at 10 ft |
|
LCD display range |
30 - 999 ppm |
|
Duration of hush mode |
About 10 min (< 300 ppm) |
|
Warm-up time |
120 seconds |
|
Interconnect |
No |
|
Operating temperature |
-10C ~ +40C |
|
Humidity range |
10%-95% RH |
Alarm sensitivity
30 ppm — no alarm within 120 minutes. 50 ppm — alarm within 60-90 minutes. 100 ppm — alarm within 10-40 minutes. 300 ppm — alarm within 3 minutes.
Packing details
For freight and carton planning.
|
112x50x120 giftbox, mm |
585x515x260 carton, mm |
100 pcs / carton |
17.4 kg gross weight / carton |
Built to EN 50291-1:2018
EN 50291-1 is the harmonized European standard for electrical carbon monoxide alarms in domestic premises, setting the sensitivity, response time, and stability requirements the LZ-2902 is tested against.