portable smoke detector alarm
Description
Product Description:
-
1 Year Battery Life
-
DC 9V Battery Operated
-
Photoelectric Chamber for Early Detection
-
Loud Alarm Signal: Features a loud alarm signal exceeding 85dB(A) at a distance of 3 meters
-
Flash Alarm Indicator
-
Test/Hush Button
-
Low Battery Signal
-
Replaceable Battery: The battery is replaceable and designed to last for 1, 3, or 5 years, depending on the model and usage.
-
Lightweight Design: Net weight of approximately 125 grams (including the battery)
-
Compact Dimensions: The device measures Ф100*37mm
Product Parameter
Model No. | LZ-1902 |
Standard | EN14604:2005/AC:2008 |
Voltage | DC 9V |
Standby current | ≤10uA |
Alarm current | ≤30mA |
Sensor type | Photoelectric |
Temperature | 0°C~+40°C |
Ambient Humidity | ≤95%R.H |
Alarm indication | Red LED & Buzzer |
Sound pressure | ≥85dB(around 3m) |
Weight | ≈126g(incl.battery) |
Product size | Φ100*37.5mm |
Installation way | Ceiling mounting |
Guidelines for Installing Smoke Alarms in Your Home:
-
Every Level of the Home:
-
Install at least one smoke alarm on each level of your home, including the basement if you have one. This ensures comprehensive coverage throughout the house.
-
-
Outside Sleeping Areas:
-
Place smoke alarms in hallways or common areas outside all sleeping areas. This ensures that occupants are alerted quickly in the event of a fire.
-
-
Inside Bedrooms:
-
Consider installing smoke alarms inside each bedroom or sleeping area. This provides an early warning, especially if the door is closed, giving occupants more time to react.
-
-
Manufacturer’s Instructions:
-
Always follow the manufacturer's instructions for installation. Different models may have specific requirements that need to be adhered to for optimal performance.
-
-
Escape Path:
-
Place alarms along your escape routes to help guide you out of the house in case of a fire. This is particularly important in low visibility conditions.
-
-
Ceiling or Wall Placement:
-
Smoke alarms should be centrally located on the ceiling. If you choose to install them on a wall, they should be placed on the ceiling side of the room, ideally 4 to 12 inches below the ceiling.
-
-
Avoid Obstructions:
-
Keep smoke alarms away from areas where they could be obstructed by furniture, curtains, or other items that could interfere with their operation.
-
-
Test Regularly:
-
Test smoke alarms monthly to ensure they are working properly. Regular testing is crucial for maintaining their reliability.
-
-
Replace Batteries:
-
Replace batteries at least once a year, or when the low battery signal sounds. This ensures that the smoke alarm remains operational.
-
-
Replace Alarms:
-
Replace smoke alarms every 10 years or as recommended by the manufacturer. Over time, the sensors in smoke alarms can become less effective, so regular replacement is necessary.
-
Additional Considerations:
-
Local Building Codes: Check with your local fire department or building inspector for any additional guidelines or specific requirements related to smoke alarm placement. Local building codes may have specific rules that need to be followed.
Applicable place
Key words:smoke alarm,Wireless 9v Fire Alarm For Home,Nest Smoke Detector