Menu
Language
All categories
      Product ID: 62305038

      smoke detector 10 years without wire

      Contact Now

      Description

      Product Description

      •10 years battery life time
      •3V (incorporating non-replaceable lithium battery)
      •Photoelectric sensing self-check
      •Loud>85db(A) alarm signal(3M)
      •Flash alarm indicator(red LED)
      •Test button
      •Low Battery signal
      •Local alarm memory
      •Nine-minute timer for nominal silence mode
      •End of life indicator
      •N.W.:56g(include battery)
      •Dimensions: Ф46*51.6mm

      Product characteristics:
      It adopts photoelectric omni-directional detection, mini-design, compact and delicate; with alarm memory function; 10years end of life warning; with test button; low voltage signal reminder.


      Product Parameter

      Model No. LZ-1951A
      Standard EN14604:2005/AC:2008
      Voltage DC 3Vnon-replaceable
      Standby current 5uA
      Alarm current 120mA
      Sensor type Photoelectric
      Temperature 0°C~+40°C
      Ambient Humidity 95%R.H
      Alarm indication Red LED & Buzzer
      Alarm memory Green/Red LED
      Hush time 8~10min
      Sound pressure 85dB(around 3m)
      Weight 56g(incl.battery)
      Product size Φ46*50mm
      Installation way Wall or Ceiling mounting

      Where fit to install Fire Alarm

      1. At first, you need install them in your bedroom and route way, and should install one item in every bedroom at least.

      2. Stairway is important for you to rush out when fires occur, so there must install smoke detectors.

      3. You at least require one smoke alarm on every floor,including finished attics and basements.

      4. Install one alarm beside every electric facility.

      5. Install smoke alarms in the middle of ceiling,because smog,heat and flashes always lift to the top of rooms.

      6. If some reasons cause you can’t install them in the middle of ceiling,you need to install them at least 10cm away from the wall.

      7. If you like to install them on the wall, they should be installed 10-30.5cm away under the ceiling. Diagram 1.

      8. You need install more than one alarm when the length of your hall exceeds 9m.

      9. In an ablique roof room,install the alarm 0.9m away from the top.Diagram 2.

      10. How to install smoke alarms in a removable house.The removable house is short of heat isolation, so you’d better install the alarm 10-30.5cm away from the ceiling.for safety you need install another one near your bedroom, too.

      Smoke Alarm Application Place

      key words:mini smart smoke alarm, 10 years battery smoke alarm




      Please Send Message

      ${currentPro.title}

      - Send