With 6 years experience supply fire detector
Description
1) Monthly Testing: Press the test button on the cover of the unit and hold it until the alarm sounds. If the alarm does not go off, check if the unit is receiving power and test it again. If it still doesn't alarm, check the battery and replace it immediately if needed.
2) Visual Indicators: The signal light on the unit flashes once every 30 seconds to indicate that it is functioning properly. When the alarm goes off, the signal light will flash once every 0.5 seconds.
3) Low Battery Warning: If the alarm emits a low "chirp" sound every 30 seconds, it means the battery needs to be replaced.
4) False Alarm: Normal smoke from cooking or small amounts of smoke will not trigger the alarm. False alarms occur only if you blow smoke directly into the alarm or if you forget to turn on ventilation while cooking.
5) Smoke Activation: Sometimes, smoking near the unit may trigger the alarm. In such cases, simply ventilate the area to stop the alarm from sounding.
Product Description DC 4.5V CO Alarm
- CO sensor fault warning
- 3 years battery life time
- Test/Hush button
- Low Battery warning
- CO concentration≥ 300 ppm will trigger alarm in 2 minutes
Product Parameter DC 4.5V CO detector for home
Model No.
LZ-2901
Standard
EN50291-1:2018
Voltage
DC 4.5V(3xAA 1.5 alkaline battery)
Standby current
≤15uA
Alarm current
≤60mA
Sensor type
Electrochemical Figaro CO Sensor
Temperature
一10°C ~ +40°C
Ambient Humidity
30~95%R.H
LED indication
Red LED & Buzzer
Hush time
8~9min
Product life
7years
Sound pressure
≥85dB(around 3m)
Weight
≈103g
Product size
Φ101*101*30mm
Installation way
Wall or Ceiling mounting
Applicable place for home security