      Hybrid Heat Recovery Ventilation with DC Inverter Heat Pump 12kW

      Contact Now

      Description

      Overview

      Basic Info.

      • Model NO. PW040-DKZLRS-B/S
      • Work Environment Low-temperature Heat Pump
      • Heat Source Air-source
      • Heating Type Multi-power Heat
      • Application Villa Family, Hotels, Factory Hospital, Student Apartments, Beauty Salons
      • Certification CE, ISO9001, CB, RoHS
      • Compressor Pana-Sonic Full DC Inverter
      • Ambinet Temp -30 Degree ~ 45 Degree
      • Type Monoblock Heat Pump
      • Heating Capacity 8.4kw, 13kw, 18.2kw, 23kw
      • Key Word Heat Pump, Air Source Heat Pump
      • Power Supply 220V/50Hz, 380V/50Hz
      • Aplication Air Heating Cooling and Hot Water
      • Refrigerant R32
      • Transport Package Plastic Bag Inside with Wooden Frame
      • Specification 105cm*52cm*97cm
      • Trademark Power World or OEM
      • Origin China
      • HS Code 84189910
      • Production Capacity 5000 Sets Per Month

      Product Description

      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      Power World ERP A+++ Full DC inverter Heat Pump for Heaing Cooling,DHW

      The EASYLIFE PLUS Series heat pumps can be used in new buildings and retrofits, both residential and commercial buildings. It is a year-round heat source for heating, cooling and domestic hot water heating purpose.

      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      Global Application Potential

      With below features, Power World Easylife Series can be widely used:

      • Heating, Cooling, and DHW functions for all year round running.
      • EVI technology ensures smooth operation from -25ºC to 43ºC.
      • Various Capacity Selection from 8 ~ 30 kW for different houses.
      • Wide Voltage Range ( 170-254V for single phase, 320-460V for 3 phase)
      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      Full DC Inverter Technology

      Power World Easylife Series adopts full inverter Panasonic twin-rotary compressor and inverter brushless motor. With this technology, users can enjoy a maximum level of comfort with the lowest costs.

      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      A+++ Energy Level

      Power World highlights higher and higher energy efficiency. Our Easylife Series has gained A+++ energy label, and passed ERP test report issued by TÜV SÜD.

      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      Intelligent Water Temperature Adjustment

      The unique control logic enables our Easylife Series to adjust the outlet water temperature intelligently, according to the real-time changing ambient temperature. Thanks to this function, our users can not only enjoy greater comfort, but also save more bills.

      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      R32 Low GWP Refrigerant

      Reducing and preventing global warming is an important mission of Power World. R32 used in our Easylife series has GWP of only one third comparing to R410A. Besides, 30% amount of refrigerant is less needed for R32 heat pump systems than R410A ones.

      Domestic Full DC Inverter Heating Pump R32 Hybrid Heat Recovery Ventilation with Heat Pump 12kw

      Product Parameters

      Model PW030-DKZLRS-B/S PW040-DKZLRS-B/S PW040-DKZLRS-B PW050-DKZLRS-B PW060-DKZLRS-B
      Heating Condition - Ambient Temp.(DB/WB): 7/6ºC,Water Temp.(In/Out):30/35ºC 3.2~8.0 4.8~12.0 4.8~12.0 7.3~18.0 8.8~22.0
      Heating Capacity Range (kW) 3.2~8.0 4.8~12.0 4.8~12.0 7.3~18.0 8.8~22.0
      Heating Power Input Range(kW) 0.61~1.88 0.93~2.88 0.93~2.88 1.36~4.14 1.67~5.15
      COP Range 4.26~5.23 4.17~5.18 4.17~5.18 4.35~5.36 4.27~5.28
      DHW Condition-Ambient Temp.(DB/WB): 7/6ºC,Water Temp.(In/Out):15/55ºC 2.9~7.2 4.3~10.8 4.3~10.8 6.0~15.0 7.4~18.5
      Heating Capacity Range (kW) 2.9~7.2 4.3~10.8 4.3~10.8 6.0~15.0 7.4~18.5
      Heating Power Input Range(kW) 0.64~1.97 0.97~3.03 0.97~3.03 1.29~4.00 1.63~5.05
      COP Range 3.65~4.54 3.56~4.45 3.56~4.45 3.75~4.64 3.66~4.55
      Cooling Condition - Ambient Temp.(DB/WB):35/24ºC,Water Temp.(In/Out):12/7ºC 2.5~6.2 3.3~8.2 3.3~8.2 5.1~12.6 6.0~15.0
      Cooling Capacity Range (kW) 2.5~6.2 3.3~8.2 3.3~8.2 5.1~12.6 6.0~15.0
      Cooling Power Input Range(kW) 0.79~2.27 1.06~3.11 1.06~3.11 1.58~4.53 1.88~5.49
      EER Range 2.73~3.15 2.64~3.10 2.64~3.10 2.78~3.23 2.73~3.19
      ErP Level (35°C) A+++ A+++ A+++ A+++ A+++
      ErP Level (55°C) A++ A++ A++ A++ A++
      Power supply 230V/1Ph/50Hz/60Hz 380V/3Ph/50-60Hz
      Diameter of pipe (mm) DN25 DN25 DN25 DN25 DN25
      Water Flow (m3/h) 1.2 1.5 1.5 2.5 2.8
      Water Pressure Drop (max) kPa 30 35 35 40 45
      Water pump type Adjustable DC inverter
      Max water head (m) 9 9 9 12 12
      Auxiliary electric heater (kW) 3 3 3 3 3
      Expansion vessel (L) 2 5 5 5 5
      Safety valve (MPa) 0.3 0.3 0.3 0.3 0.3
      Noise dB(A) ≤45 ≤48 ≤48 ≤53 ≤55
      Net Weight (kg) 105 115 115 160 165
      Net Dimension (L/W/H) mm 1150×460×820 1150×460×960 1150×460×960 1260×480×1060 1260×480×1060
      Operation Ambient Temp. (ºC) -30~43ºC
      Operating water temperature (ºC) 20~55ºC (DHW)
      Operating water temperature (ºC) 20~50ºC (Heating)
      Operating water temperature (ºC) 7~35ºC (Cooling)